PureFlo
PureFlo PF50 ESM+ PAPR, Cleanroom Lab NIOSH Safety Respirator
- Part Number:
- GT-PR05802-G-0A2
- Lead Time:
- Call for availability: 3-6 weeks
- Minimum Purchase:
- 1 unit
- Shipping:
- FREE SHIPPING on most orders over $50*
- Quantity:
- each
- Color:
- black
Bulk discount rates
Automatically save when you buy in bulk.
Buy 6 - 11 | and get 10% off |
Buy 12 or above | and get 15% off |
Description
Please note: we do not accept returns for this item.
PureFlo PF50 ESM+ PAPR Respirator Hood for laboratory, cleanroom and pharmaceutical use. The all-in-one, head mounted PureFlo® ESM+ Powered Air Purifying Respirators are the next generation of the industry leading ESM PAPRs. A self-contained, head mounted, powered air purifying respirator designed for use in light-duty industries including pharmaceutical, chemical, laboratory and healthcare. Includes a built-in electronic system and a unique air circulator system.
Your choice of HEPA (HE) filter or a combination HE/HF/HC filter (Hydrogen Fluoride and Hydrogen Chloride); both remove 99.97% of liquid or solid based contaminants; effective for removal of nuisance odors from organic vapor
No belt-mounted blower unit required, which improves comfort and makes the PAPR ideal for use with a range of protective workwear. The air circulation system creates a smooth continuous flow of air that draws air from surrounding environment through filter located at rear of helmet. Refined, built-in Electronic System Management (ESM) continually monitors all functions and provides a self-diagnostic system check to ensure proper functioning at all times. A simple LED user interface features an audio alarm. During use, the LED will remain green if the unit is operating normally; if it flashes red fast, and you hear three fast tones, this indicates low airflow or that there is no filter fitted; if it slowly flashes red, with two slow tones, it means the battery is low. Face shield of high-impact resistant polycarbonate has anti-scratch coating on both sides and provides protection against impact, high impact, and splashes. Each unit contains a fully capsuled blower module with a single 7-way IP67** connector between the sidebars and blower/motor unit with a standard internal on/off switch.
Key Features
- Package includes: 2 battery chargers, 2 battery packs, 1 HEPA filter (or HE/HF/HC filter), Instruction manual and Warranty Information
- Lightweight self-contained PAPR provides freedom of movement and increases worker acceptance:
- Can be worn in tight spaces because there are no belts, hoses, or other snag hazards
- Can be worn with fall protection harnesses without interference
- Adjustable Neck Cape, when sealed, creates self-contained positive pressure environment, providing additional protection to the lower face and neck area with an APF of 1000. Cape can be ordered in the follow materials:
- Integrity 1800 polyester fabric for use in laboratories and pharmaceutical clean room environments
- Densely woven continuous filament polyester fabric with an ESD stripe designed to meet the quality and performance standards in critical Cleanroom environments around the world
- Highly fluid repellent (Teflon® HT treatment) and also contains a durable antimicrobial treatment (Aegis) to inhibit bacterial growth and reduce bioburden
- Recommended for pharmaceutical, biotech and similar applications — Class 10 (ISO Class 4) and high
- Can be laundered
- Disposable Tychem QC for Petroleum, Pulp and Paper, Food and Chemical Processing, and Pharma industries
- Chemical resistance polyethylene-coated Tyvek®
- Protects against light liquid splash with at least 30 minutes of protection against more than 40 chemicals
- Protects against biological hazards: exposure to blood borne pathogens, pandemic preparedness, etc.
- Integrity 1800 polyester fabric for use in laboratories and pharmaceutical clean room environments
- Long-lasting battery life
- High, smooth air flow rate:
- Delivers air at 7.6 CFM into the breathing zone under normal circumstances
- Booster switch can be manually activated to increase airflow to 8.2 CFM or 230 L/m for hotter/ extreme working conditions
- Choice of HEPA (HE) filter or a combination HE/HF/HC filter (Hydrogen Fluoride and Hydrogen Chloride) ; both remove 99.97% of liquid or solid based contaminants; effective for removal of nuisance odors from organic vapors.
- Altitude sensor adjusts flow rate
- APF 1000* Head, Eye/Face protection: ANSI Z87.1+ :2015
- Highly adjustable Quick Release Headband offers maximum comfort, fit, and stability
- Quick and fail-proof filter changes
- Quick-clean headtop eliminates disposal of paper hoods, which lowers ongoing cost
- Highly durable with rust-proof hardware
- Internal power switch is recommended for maximum safety. External switches are also available
- Heat protection and accessories are available
Technical Specifications for the PureFlo PF50 ESM+ PAPR
PAPR | NIOSH approved 42 CFR 84 |
Weight | Without filter or batteries = 2.372 lb |
With filter and batteries ~ 3.5 lb | |
Noise level | Less than 70 dB |
Airflow rate | Up to 8.2 CFM / 230 Liter/Min |
Eye and Face Protection / Face Shield | ANSI Z87.1+ :2015 Certified; SEI Certified and Listed |
Respiratory | NIOSH 42CFR84 |
Filter Type | HEPA (HE) or HEPA/HF/HC *Nuisance OV |
Flow Rate | 8.1 CFM or 230 Liters/Min |
Noise Level | Under 70dB |
Assigned Protection Factor (APF) | APF 1000 Neck Cape or APF 25 Loose Fitting Face Shield |
FM Nonincendive US and Canada | Class I, II, III, Div 2, Groups ABCDEFG |
Head Size Range | 6 3/8" - 7 7/8" or 54 - 61cm |
Charger Specifications | 110V/240V AC/50 or 60 Hz/200 mA |
Battery Type | 5 Cell Nickel Metal Hydride 6v, 2.2 Ah per pack |
Battery Duration | Up to 7 Hours with Two Batteries |
Recharge Time | 2.5 Hours from Full Discharge |
Industries and Applications
PureFlo products are widely used and preferred by customers in a wide range of industries. The PureFlo ESM+ PF50 PAPR is ideal for light duty industries, and the PureFlo ESM+ PF60 PAPR is ideal for medium and heavy-duty industries, both supporting numerous applications:
Industry | Key Applications | Target Hazards |
Manufacturing | Fabrication | Respirator Hazard Particulate Dust |
Welding | Manganese Exposures In Stainless Welding | |
Sanding | Hexavalent Chromium Issues | |
Oil / Gas | Catalyst Change out | Respiratory / Chemical Splash |
Chemical / Petrochemical | Acid Line Breaking | Chemical / Acid Splash |
Aluminum Alkyls Pyrophoric Flash | ||
Pharmaceutical Industries | Cleanroom Tasks | Respiratory Hazard Particulate Dust |
Construction | Concrete Cutting | Silica Dust Exposures |
Eye / Face / Head Injuries | ||
Steel / Aluminum Mills | Ox Lancing | |
Foundries | Grinding | Beryllium and Lead Exposures |
Sanding | ||
Nuclear | Abatement | Radioactive Dust |
Mining | Removal | Silica Dust Exposures |
Paper Mills | Torch Cutting | |
Health Care | Pandemic Preparedness Response | Biological Hazards (i.e. exposure to blood and bloodborne pathogens) |
Laboratories | Cleanroom Tasks | Respirator Hazard Particulate Dust |
Lead Cleanup | Lead Dust | |
Arc Gouging |
Filter Installation Notes
- Do not open packaging until ready to install the filter or cartridge
- Do not replace filter or cartridge with the unit running
- Filter must be replaced when the LED Indicator Light blinks
- Be careful to not cross contaminate interior of helmet during replacement
- Avoid cross-threading during installation
Protective Neck Cape options
Standard Black STEDPRENE® FR Material
| |
White Integrity 1800 Material Single or Double Bib
| |
Disposable Neck Cape White Tychem 2000 (QC) Single or Double Bib
|
Commonly Asked Questions
What is a PAPR?
A Powered Air Purifying Respirator is battery-operated safety equipment, consisting of a facepiece, battery-operated blower, and particulate filters. A PAPR uses a blower to pass contaminated air through a HEPA filter, which removes the contaminant and supplies purified air to a facepiece.
Isn't an all-in-one system too heavy for comfort?
Until proper adjustments are made, the PureFlo may seem heavy. However, the key to comfort is the center of gravity and weight distribution on a worker's head. PureFlo ESM+ utilizes a high quality, adjustable, quick-release headband, which can be adjusted to comfortably fit the workers head via ratchet adjustment. Other contributing factors include the height of the unit, which can be raised or lowered, and adjusted forward or backward.
Isn't the PureFlo more expensive than other options?
Actually, the long lifetime, superior quality and performance, ease of use, and reduced maintenance make these premium PureFlo PAPRs less expensive over time than many common alternatives, despite the upfront cost.
Can I upgrade an older model?
Yes, we can help existing PureFlo ESM PAPR customers get the benefits of the new ESM+ PAPRs, Gentex Corporation is offering an upgrade kit! Contact us for a quote.
* The employer must have evidence provided by the respiratory manufacturer that testing of these respirators demonstrates performance of a level of protection of 1,000 or greater to receive an APF 1,000. This level of performance can best be demonstrated by performing a workplace protection factor (WPF) or simulated workplace protection factor (SWPF) study or equivalent testing.
**IP67 = 6 – protection against dust / 7- protection against the effect of immersion between 15 cm and 1m
- The double bib has an added inner piece of the neck cape that allows the user to tuck it inside a coverall